  1. Flexible gas piping OK for exterior? - InterNACHI®️ Forum

    Aug 1, 2007 · Does anyone know if CSST - the corrugated stainless steel flexible gas line - approved for exterior installation? Thank you in advance!

  2. Proper CSST bonding - Plumbing Inspections - InterNACHI®️ …

    Dec 29, 2010 · The goal of bonding the gas pipe is “equipotential” with the electrical ground and that can not be achieved with two different rods. Lightning induced arcing can jump from …

  3. CSST through solid wall - Plumbing Inspections - InterNACHI®️ …

    Apr 15, 2014 · The thread title says “CSST through solid wall.” If this is the question, the answer is “yes,” CSST can pass through a solid wall. CSST can also be directly connected to fixed …

  4. CSST installed in furnace cabinet - InterNACHI®️ Forum

    Feb 7, 2020 · The CSST connection shall be made outside of the metallic gas appliance enclosure to a section of rigid metallic pipe, stub‐out, or termination fittings. So the question …

  5. gas line in concrete - Plumbing Inspections - InterNACHI®️ Forum

    Sep 5, 2009 · Can flex gas lines be installed in concrete this way? I don’t see how concrete would damage the line but is a protective sleeve needed for this application?

  6. Bonding of csst gas line - InterNACHI®️ Forum

    Jun 18, 2020 · Would appreciate some clarity on CSST bonding- a number of the posts I have read are confusing to me anyway. Is the clamp that is secured to the first csst fitting coming …

  7. Gas Pipe Materials - Plumbing Inspections - InterNACHI®️ Forum

    Jan 26, 2020 · The home had corrugated stainless steel tubing (CSST) installed as gas distribution pipe. CSST is a thin-walled, semi-rigid, corrugated stainless steel tubing covered …

  8. Flexible gas appliance connector - InterNACHI®️ Forum

    Apr 9, 2014 · Rigid metallic pipe and fittings. Corrugated stainless steel tubing (CSST) where installed in accordance with the manufacturer’s instructions. Semirigid metallic tubing and …

  9. Does CSST need the plastic coating around it? - InterNACHI®️ …

    Jan 15, 2020 · Yes it does. The Stainless steel tubing is thin and requires the vinyl coating for protection. CSST isn’t rated for exterior use and the deterioration in your picture is exactly …

  10. CSST passing through wall - Plumbing Inspections

    May 7, 2012 · Is it OK for CSST to pass through a wall? I would think a sleeve is required? What are the applicable code sections? Thanks.